中國醫藥大學機構典藏 China Medical University Repository, Taiwan:Item 310903500/721
English  |  正體中文  |  简体中文  |  Items with full text/Total items : 29490/55136 (53%)
Visitors : 1995268      Online Users : 505
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version
    Please use this identifier to cite or link to this item: http://ir.cmu.edu.tw/ir/handle/310903500/721


    Title: 三成份部份互溶有機水溶液之閃火點預測模式;A mathematical model for predicting the flash point of ternary partially miscible mixtures of aqueous-organic system
    Authors: 吳弦達;Hsuan-Ta Wu
    Contributors: 中國醫藥大學:職業安全衛生學系碩士班
    Keywords: 閃火點;部分互溶溶液;預測;氣-液-液平衡;氣-液平衡;Flash point;Partially miscible mixtures;Prediction;Vapor-Liquid-Liquid equilibrium;Vapor-Liquid equilibrium
    Date: 2009-07-06
    Issue Date: 2009-08-12 15:21:02 (UTC+8)
    Abstract: 閃火點為描述液體火災爆炸的重要資訊。部分互溶混合溶液主要使用在非勻相蒸餾製程和液液萃取程序中。本研究目的在建立多成份部份互溶有機水溶液之閃火點預測模式。使用水 + 乙醇 + 正丁醇、水 + 正丁醇 + 2-丁醇以及水 + 乙醇 + 2-丁醇之三種有機水溶液實驗數據來驗證模式的預測能力。
    模擬過程利用VLLE參數來推估Tie Line及其閃火點,VLE參數被使用來推估互溶區的閃火點。此閃火點預測模式經實驗數據驗證,在模擬過程中不但能有效的估計互溶區及部份互溶區的範圍,並且能預測每條Tie Line上的閃火點為一定值。

    Flash point is a variable used in characterizing fire and explosion hazard of liquids. The partially miscible mixtures are used in heterogeneous distillation process and liquid-liquid extraction process. The purpose of this study is to build a mathematical model to predict the flash point of the ternary partially miscible mixtures of aqueous-organic system. The proposed model was validated by use of water +ethanol + 1-butanol, water + ethanol + 2-butanol and water + 1-butanol + 2-butanol mixtures.
    The VLLE parameters were used to estimate the span of the tie lines and their flash point, and the VLE parameters were used to estimate the flash point in mutual solubility region. The flash point prediction model was verified by the experimental data to be able to estimate the range of the miscible and partially miscible phase during the simulation, as well as the constant flash point on each tie line.