English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 29490/55136 (53%)
造訪人次 : 1505356      線上人數 : 305
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋
    主頁登入上傳說明關於CMUR管理 到手機版
    請使用永久網址來引用或連結此文件: http://ir.cmu.edu.tw/ir/handle/310903500/30937


    題名: Synthesis and cytotoxicity of 2-acetyl-4,8-dihydrobenzodithiophene-4,8-dione derivatives
    作者: Chao, YH;Kuo, SC;Wu, CH;Lee, CY;Mauger, A;Sun, IC;Morris-Natschke, SL;Lee, KH
    貢獻者: 藥學院藥化所;China Med Coll, Grad Inst Pharmaceut Chem, Taichung 400, Taiwan;Univ N Carolina, Sch Pharm, Div Med Chem & Nat Prod, Nat Prod Lab, Chapel Hill, NC 27599 USA;NCI, Drug Synth & Chem Branch, NIH, Bethesda, MD 20892 USA
    日期: 1998
    上傳時間: 2010-09-24 15:06:56 (UTC+8)
    出版者: AMER CHEMICAL SOC
    摘要: The short insulin tolerance test (SITT) is described as a simple method to measure insulin sensitivity. To investigate the safety and reproducibility of the SITT, 16 healthy volunteers underwent two SITTs within 1 week. Intravenous insulin (0.05 U kg(-1) body weight) was injected into an antecubital vein. Blood samples were collected from the contralateral antecubital vein. The insulin-induced glucose disposal rate (K-itt) was calculated from the slope of the regression line of the logarithm of blood glucose against time during the first 3-15 min. Plasma glucose concentrations fell below 2.8 mmol l(-1) in 4 of the 32 tests and below 2.2 mmol l(-1) in 1 of these 4. Five subjects had mild hypoglycaemic symptoms, three of whom had plasma glucose concentrations below 2.8 mmol l(-1) in at least one SITT. The mean K-itt was 4.2 % min(-1) (range 0.8-8.4) for the first test and 3.4 % min(-1) (range 0.1-6.8) for the second test. The mean within-subject coefficient of variation was 30.7 %. We conclude that SITT should be applied with caution especially on insulin sensitive subjects and has poor reproducibility using 0.05 U kg(-1) body weight of insulin injection, venous sampling, uncontrolled physical activity and uncontrolled dietary composition. Whether 0.1 U kg(-1) body weight of insulin injection and arterialized venous blood sampling as in the original description of this test can improve the reproducibility of the SITT needs further investigation. (C) 1998 John Wiley & Sons, Ltd.
    關聯: JOURNAL OF MEDICINAL CHEMISTRY 41(23):4658-4661
    顯示於類別:[藥物化學研究所] 期刊論文

    文件中的檔案:

    沒有與此文件相關的檔案.



    在CMUR中所有的資料項目都受到原著作權保護.

    TAIR相關文章

     


    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回饋