Nitrated polycyclic aromatic hydrocarbons (NPAHs) in airborne particulate were determined by column liquid chromatography with electrochemical detection. NPAHs were extracted ultrasonically prior to being injected into the separation system. A reversed-phase C-18 column was used to separate the NPAHs with an aqueous eluent containing acetonitrile and sodium monochloroacetate as buffer. Calibration graphs were linear with very good correlation coefficients (r>0.999) and the detection limits were ca. 20 pg for all analytes. The proposed method provides a relatively simple and convenient procedure for determining the NPAHs in airborne particulate. (C) 2000 Elsevier Science B.V. All rights reserved.