English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 29490/55136 (53%)
造訪人次 : 1503838      線上人數 : 210
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋
    主頁登入上傳說明關於CMUR管理 到手機版
    請使用永久網址來引用或連結此文件: http://ir.cmu.edu.tw/ir/handle/310903500/30651


    題名: Effects of Fructus schizandrae on cycloheximide-induced amnesia in rats
    作者: Hsieh, MT;Tsai, ML;Peng, WH;Wu, CR
    貢獻者: 藥學院中藥所;China Med Coll, Inst Chinese Pharmaceut Sci, Taichung, Taiwan
    日期: 1999
    上傳時間: 2010-09-24 14:59:25 (UTC+8)
    出版者: JOHN WILEY & SONS LTD
    摘要: The purpose of this study was to investigate the effect of electroacupuncture stimulation (EA) of different frequency on pulse rate and skin temperature. Sixteen healthy male medical student volunteers received EA of 2 Hz, and 100 Hz, respectively on the both Zusanli acupoints (St-36) while resting. Their pulse rates were measured on the middle finger, and skin temperature was taken between the thumb and index finger before, during, and after EA stimulation. Each test took 35 minutes. The initial 10 min were defined as baseline period (no EA), the following 15 min as the EA period and the last 10 min as the post-EA period. Three assessments were performed on each subject as follows. A) control assessment: no EA was done throughout the test; B) 2 Hz EA assessment: 2 Hz EA was applied to both Zusanli acupoints during the EA period; and C) 100 Hz EA assessment: 100 Hz EA was applied to both Zusanli acupoints during the EA period. Our results indicate that both 2 Hz EA and 100 Hz EA decreased pulse rates during the EA period, and these changes remained throughout the post-EA period in 2 Hz EA assessment, but not in 100 Hz EA assessment. Both 2 Hz and 100 Hz EA resulted in decreases of skin temperature during the EA period. Our conclusions are that 2 Hz EA and 100 Hz EA applied to both Zusanli acupoints resulted in the decrease of pulse rate, which possibly evoked greater parasympathetic nerve activity on heart beats. 2 Hz EA had a more sustained effect on heart beats than 100 Hz EA. Decreased skin temperatures in the EA period may have resulted from cutaneous vasoconstriction caused by EA induced sympathetic stress response, suggesting EA at least remains for 15 min in clinical application.
    關聯: PHYTOTHERAPY RESEARCH 13(3):256-257
    顯示於類別:[中國藥學研究所(已停用)] 期刊論文

    文件中的檔案:

    沒有與此文件相關的檔案.



    在CMUR中所有的資料項目都受到原著作權保護.

    TAIR相關文章

     


    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回饋