    题名: Ablation centration after active eye tracker-assisted LASIK and comparison of flying-spot and broad-beam laser.
    作者: 林正明(Lin Jane-Ming);陳文祿(Wen-Lu Chen);江鈞綺(Chun-Chi Chiang)*;蔡宜佑(Yi-Yu Tsai)*
    贡献者: 中醫學院中醫學系學士班中醫內科學科;中國附醫眼科部
    日期: 2008-08
    上传时间: 2009-08-20 17:58:04 (UTC+8)
    摘要: PURPOSE: To evaluate ablation centration of flying-spot LASIK, investigate the effect of patient- and surgeon-related factors on centration, and compare flying-spot and broad-beam laser results. METHODS: This retrospective study comprised 173 eyes of 94 patients who underwent LASIK with the Alcon LADARVision4000 with an active eye-tracking system. The effective tracking rate of the system is 100 Hz. The amount of decentration was analyzed by corneal topography. Patient- (low, high, and extreme myopia; effect of learning) and surgeon-related (learning curve) factors influencing centration were identified. Centration was compared to the SCHWIND Multiscan broad-beam laser with a 50-Hz tracker from a previous study. RESULTS: Mean decentration was 0.36+/-0.18 mm (range: 0 to 0.9 mm). Centration did not differ in low, high, and extreme myopia or in patients' first and second eyes. There were no significant differences in centration between the first 50 LASIK procedures and the last 50 procedures. Comparing flying-spot and broad-beam laser results, there were no differences in centration in low myopia. However, the LADARVision4000 yielded better centration results in high and extreme myopia. CONCLUSIONS: The Alcon LADARVision4000 active eye tracking system provides good centration for all levels of myopic correction and better centration than the Schwind broad-beam Multiscan in eyes with high and extreme myopia.
    關聯: JOURNAL OF REFRACTIVE SURGERY 24(4):371~376