English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 29490/55136 (53%)
造訪人次 : 1855118      線上人數 : 333
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋
    主頁登入上傳說明關於CMUR管理 到手機版
    請使用永久網址來引用或連結此文件: http://ir.cmu.edu.tw/ir/handle/310903500/29548


    題名: Prediction of asymptomatically poor muscle perfusion of lower extremities in patients with type II diabetes mellitus using an objective radionuclide method
    作者: Lin, CC;Chang, CT;Li, TC;Kao, CH
    貢獻者: 附設醫院核子醫學部;China Med Coll, Dept Nucl Med, Taichung, Taiwan;China Med Coll, Div Endocrinol & Metab, Taichung, Taiwan;China Med Coll, Dept Nucl Med, Taichung, Taiwan;China Med Coll, Inst Chinese Med, Taichung, Taiwan
    日期: 2002
    上傳時間: 2010-09-24 14:37:30 (UTC+8)
    出版者: MARCEL DEKKER INC
    摘要: Background/Aim: Cutaneous electrical stimulation has been reported to be as effective as electroacupuncture. The aim of this study was to test whether cutaneous electrical stimulation had the same effect as electroacupuncture to enhance the regularity of myoelectrical activity. Methods: Fifteen healthy male volunteers were enrolled for this study. Electrogastrography (EGG) was performed for 30 min at the baseline, 30 min during electroacupuncture or cutaneous electrical stimulation, and for an additional 30 min thereafter. Results: During 3 Hz of electroacupuncture on the Zusanli point, there was a significant increase in the percentage of normal frequency. The percentage of normal frequency in the post-acupuncture period was also increased, but it was not statistically significant when compared to the baseline. There was a significant decrease in the tachygastric and bradygastric rhythm during electroacupuncture on the Zusanli points. There were similar changes of EGG parameters with cutaneous electrical stimulation on the Zusanli points. The percentage of normal frequency during cutaneous electrical stimulation increased significantly. However, the percentage of normal frequency in the post-cutaneous electrical stimulation period was similar to the baseline. There was a significant decrease in the percentage of tachygastric rhythm during cutaneous electrical stimulation on the Zusanli points. However, there was no significant change in the percentage of bradygastric rhythm during and after the cutaneous electrical stimulation periods. Conclusions: The effect of cutaneous electrical stimulation on the percentage of normal frequency and tachygastria is similar to electroacupuncture. Nonetheless, the changes of the percentage in bradygastria are not significant. Copyright (C) 2002 S. Karger AG, Basel.
    關聯: ENDOCRINE RESEARCH 28(3):265-270
    顯示於類別:[台中附設醫院] 期刊論文

    文件中的檔案:

    沒有與此文件相關的檔案.



    在CMUR中所有的資料項目都受到原著作權保護.

    TAIR相關文章

     


    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回饋