    题名: Bone position estimation from skin marker co-ordinates using global optimisation with joint constraints
    作者: Lu, TW;O'Connor, JJ
    贡献者: 健康照護學院物治系;China Med Coll, Sch Phys Therapy, Taichung 404, Taiwan;Univ Oxford, Oxford Orthopaed Engn Ctr, Oxford, England;Univ Oxford, Dept Engn Sci, Oxford OX1 3PJ, England
    关键词: Bone position;Multi-link models;Kinematics;Optimisation;Joint constraints
    日期: 1999
    上传时间: 2010-09-24 14:27:39 (UTC+8)
    出版者: ELSEVIER SCI LTD
    摘要: Acupuncture at the Zhongwan acupoint has been widely used in traditional Chinese medicine to relieve symptoms of diabetes mellitus. Our study investigated the effect on plasma glucose of electroacupuncture applied at the Zhongwan acupoint in rat diabetic models. Plasma concentrations of insulin, glucagon and beta-endorphin- were also determined using radioimmunoassay. A decrease in plasma glucose was observed in rats after electroacupuncture (15 Hz, 10 mA) for 30 min at the Zhongwan acupoint. This was observed in normal rats and rat models with Type II (non-insulin-dependent) diabetes mellitus. No significant effect on plasma glucose was observed in rat models with Type I (insulin-dependent) diabetes mellitus; neither the streptozotocin (STZ)-induced diabetic rats nor the genetic (BB/W) rats. Further, the hypoglycaemic action of electroacupuncture stimulation disappeared in rats with insulin-resistance induced by an injection of human long-acting insulin repeated daily to cause the loss of tolbutamide-induced hypoglycaemia. An insulin-related action can thus be hypothesised. This hypothesis is supported by an increase in plasma insulin-like immunoreactivity after electroacupuncture stimulation in normal rats. Participation of glucagon was ruled out because there was no change in plasma glucagonlike immunoreactivity resulting from electroacupuncture stimulation. In addition to an increase in plasma beta-endorphin-like immunoreactivity, the plasma glucose lowering action of electroacupuncture stimulation at Zhongwan acupoint was abolished by naloxone in a sufficient dose to block opioid receptors. Thus we suggest that electroacupuncture stimulation at the Zhongwan acupoint induces secretion of endogenous beta-endorphin which reduces plasma glucose concentration in an insulin-dependent manner.
    Widespread use of gait or motion analysis in the diagnosis of patients with locomotor pathology and the subsequent planning and assessment of treatment has been limited because of its reliability, particularly in evaluating frontal and transverse plane components. This is because spatial reconstruction of the musculoskeletal system and calculation of its kinematics and kinetics via a skin marker-based multi-link model are subject to marker skin movement artefacts. Traditional methods treat each body segment separately without imposing joint constraints, resulting in apparent dislocations at joints predominantly because of skin movement artefacts. An optimisation method for the determination of the positions and orientations of multi-link musculoskeletal models from marker co-ordinates is presented. It is based on the minimisation of the weighted sum of squared distances between measured and model-determined marker positions. The model imposes joint constraints. Numerical experiments were performed to show that the new method is capable of eliminating joint dislocations and giving more accurate model position and orientation estimations. It is suggested that, with joint constraints and a global error compensation scheme, the effects of measurement errors on the reconstruction of the musculoskeletal system and subsequent mechanical analyses can be reduced globally. The proposed method minimises errors in axial rotation and ab/adduction at the joints and may extend the applicability of gait analysis to clinical problems.
    關聯: JOURNAL OF BIOMECHANICS 32(2):129-134