題名: | Increased lung uptake of technetium-99m hexamethylpropylene amine oxime in diffuse infiltrative lung disease |
作者: | Hang, LW;Shiau, YC;Hsu, WH;Tsai, JJP;Yeh, JJ;Kao, A |
貢獻者: | 附設醫院內科部呼吸治療科;China Med Coll Hosp, Div Pulm & Crit Care Med, Taichung 404, Taiwan;China Med Coll Hosp, Dept Med Res, Taichung 404, Taiwan;Far Eastern Mem Hosp, Dept Nucl Med, Taipei, Taiwan;Taichung Healthcare & Management, Grad Inst Bioinformat, Taichung, Taiwan;Ping Tung Christian Hosp, Dept Thorac Med, Pingtung, Taiwan;Mei Ho Inst Technol, Pingtung, Taiwan |
日期: | 2003 |
上傳時間: | 2010-09-24 14:20:07 (UTC+8) |
出版者: | KARGER |
摘要: | The disinfection of hospital wastewaters using the ozonization process was studied. The concentrations of ozone required to reach a sudden drop of coliform and Pseudomonas aeruginosa in the wastewater are 4.0-7.0 and 3.0-5.0 mgL(-1), respectively. For the hospital wastewater, the disinfection efficiencies were 0.518S(-1.1) for coliforms, 0.509S(-1.06) for Pseudomonas aeruginosa and 0.254S(-1.54) for total count, respectively. As to the effects of ozone input methods on the disinfection efficiency, the continuous ozonization process was ten times higher than the batch input process. The low COD removal rate was obtained at 25.0 mgL(-1) of ozone concentration for hospital wastewater. However, more biodegradable compounds resulted in the treated mixture. |
關聯: | RESPIRATION 70(5):479-483 |