中國醫藥大學機構典藏 China Medical University Repository, Taiwan:Item 310903500/29049
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 29490/55136 (53%)
造访人次 : 1909504      在线人数 : 400
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻
    主页登入上传说明关于CMUR管理 到手机版


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.cmu.edu.tw/ir/handle/310903500/29049


    题名: Feasibility and accuracy of pre-procedure imaging of the proximal cephalic vein by duplex ultrasonography in pacemaker and defibrillator implantation
    作者: Chen, JY;Chang, KC;Lin, YC;Chou, HT;Hung, JS
    贡献者: 附設醫院內科部心臟科;China Med Univ Hosp, Dept Med, Div Cardiol, Taichung, Taiwan
    日期: 2004
    上传时间: 2010-09-24 14:19:47 (UTC+8)
    出版者: KLUWER ACADEMIC PUBL
    摘要: Spiculation is a stellate distortion caused by the intrusion of breast cancer into surrounding tissue. Its existence is an important clue to characterizing malignant tumors. Many successful mammographic methods have been proposed to detect tumors with spiculation. Traditional two-dimensional (2-D) ultrasound cannot easily find spiculations because spiculations normally appear parallel to the surface of the skin. Recently, three-dimensional (3-D) ultrasound has been gradually used in clinical applications and it has been proven to be useful in determining the architectural distortion or spiculation that surrounds a breast tumor. This paper aims to identify spiculation from 3-D ultrasonic volume data of a tumor found by a physician. In the proposed method, each coronal slice of volume data is successively extracted and then analyzed as a 2-D ultrasound image by the proposed spiculation detection method. First, in each horizontal slice, the modified rotating structuring element (ROSE) operation is used to rind the central region in which spiculation lines converge. Second, the stick algorithm is used to estimate the direction of the edge of each pixel around the central region. A pixel whose edge points toward the central region is marked as a potential spiculation. Finally, the marked pixels are collected around the central region and their distribution is analyzed to determine whether spiculation is present. The 3-D test datasets were obtained using the Voluson 530 or 730, Kretztechnik, Austria. First, the proposed method was tested on 104 2-D typical coronal images (selected by an experienced physician) extracted from 52 3-D ultrasonic datasets. Finally, 225 3-D pathologically proven datasets were tested to evaluate the performance. Spiculations are more easily observed in the coronal view than in the other two views. That is, the 3-D ultrasound is a powerful tool for identifying spiculations. Furthermore, 16% (19/120) of benign cases and 90% (94/105) of malignant cases are detected as spiculations.
    關聯: JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY 10(1):31-35
    显示于类别:[台中附設醫院] 期刊論文

    文件中的档案:

    没有与此文件相关的档案.



    在CMUR中所有的数据项都受到原著作权保护.

    TAIR相关文章

     


    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈