資料載入中.....
|
請使用永久網址來引用或連結此文件:
http://ir.cmu.edu.tw/ir/handle/310903500/2505
|
題名: | In vivo tension sustained by fascial sling in pubovaginal sling surgery for female stress urinary incontinence. |
作者: | 陳階曉(CHIEH-HSIAO CHEN);陳汶吉(Chen,Wen-Chi);吳錫金(Wu,His-Chin);張兆祥(Chang,Chao-Hsian) |
貢獻者: | 中國附醫泌尿部 |
關鍵詞: | fascia;urinary incontinence, stress;tensile strength |
日期: | 2005-10 |
上傳時間: | 2009-08-20 17:31:19 (UTC+8) |
摘要: | Purpose:
In pubovaginal sling surgery arguments have focused on selecting stronger sling materials, better suturing methods and superior fixation techniques. However, the grounding information prerequisite for these arguments is still lacking, ie the in vivo tension sustained by the sling. We designed this study to obtain this information.
Materials and Methods:
A total of 10 female patients (mean age 65.4 years) underwent pubovaginal sling surgery while under epidural anesthesia. A strip of rectus fascia (2 × 6 cm) was isolated. Each end of the fascia was anchored with a 1-zero Prolene suture (Ethicon, Somerville, New Jersey). The fascial sling was placed over the proximal urethra. Both ends of the prolene (polypropylene) sutures were transferred to the lower abdominal incision and tied on each other. The fascial sling was adjusted just to touch the proximal urethra without elevating it. We hooked the tied polypropylene suture on a digital force gauge to measure the tension sustained by the fascial sling. Patients were instructed to cough, and the tension was measured at different bladder volumes (100, 200, 300, 400 ml) and in 2 positions (horizontal and operative table tilted head-up 20 degrees). Intravesical pressure was monitored with a pressure transducer to ensure adequate cough strength. We also investigated the in vitro length-tension relationship and tensile strength of 3 rectus fascia strips (0.5 × 6 cm) obtained from 3 of these patients.
Results:
Mean tension ± SEM sustained by the fascial sling during cough in the horizontal position was 0.046 ± 0.004, 0.043 ± 0.006, 0.0475 ± 0.006 and 0.0485 ± 0.007 kg at 100, 200, 300 and 400 ml bladder volume, respectively. Bladder volume did not statistically affect the sustained tension. The 20-degree head-up position also did not statistically change the tension sustained. In vitro study showed that the fascia strip could be stretched for a mean of 0.4 cm before sling tension began to increase. A mean load of 2.4 kg broke 0.5 × 6 cm strips.
Conclusions:
In the horizontal and mild tilting positions during an increase in intra-abdominal pressure, the fascial sling only sustains minor tension, which is far less than the maximal load needed to break fascial strips. The excellent elasticity of the fascia may dissipate the straining force and partly explains the measured small sustained tension. |
關聯: | JOURNAL OF UROLOGY 174(3):894~897 |
顯示於類別: | [台中附設醫院] 期刊論文
|
文件中的檔案:
檔案 |
大小 | 格式 | 瀏覽次數 |
| 58Kb | Unknown | 534 | 檢視/開啟 |
|
在CMUR中所有的資料項目都受到原著作權保護.
|