中國醫藥大學機構典藏 China Medical University Repository, Taiwan:Item 310903500/19526
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 29490/55136 (53%)
造访人次 : 1507617      在线人数 : 738
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻
    主页登入上传说明关于CMUR管理 到手机版


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.cmu.edu.tw/ir/handle/310903500/19526


    题名: Stress Analysis of 3D Dental Bridge Models with Various Implant Supported Designs
    作者: (Chih-Han Chang)*;黃恆立(Heng-Li Huang);(Chun-Li Lin);(Ching-Chang Ko)
    贡献者: 醫學院牙醫學系
    日期: 2002-03-06
    上传时间: 2009-09-07 09:16:12 (UTC+8)
    摘要: The purpose of this study was to investigate the effects of (1) the bite forces for both force direction and location, and (2) the implant designs such as alignment and size of the implants on stress distribution of the implant-supported partial prostheses. Three dimensional finite element models were constructed by the combination of the computed tomographic (CT) images of a human mandible and the CAD graphs of cylindrical dental implants. Variations such as the implant alignment (e.g., in-line or off-line) and implant diameter were analyzed. All models were meshed with quadrics tetrahedral elements and the nodes at the bottom surfaces of the mandibular bone were constrained in x, y, and z directions. The results were, in general, consistent with those reported in literature, showing that high stress regions were located at the neck of and the alveolar crest around the implants. The stress concentration patterns appeared to concur with the clinical observations for the implant fracture sites and the initial location of alveolar bone loss. The wider implant diameter reduced stress magnitudes in both the implant neck and the alveolar crest. This was partially due to the increased implant-bone contact area and the large moment inertia of wide implant. The oblique force yielded much higher (five times) stresses in cortical bone than the vertical force. However, the off-line implant alignment alone did not always delineate values. There exists a complicated interaction between implant alignment, loading direction and the shape of mandible block simulated. Further studies analyzing synergistic effects of all factors are currently under investigation.
    關聯: 80th General Session of the International and American Associatio
    显示于类别:[牙醫學系暨碩博士班、口腔醫學產業碩士班] 會議論文

    文件中的档案:

    没有与此文件相关的档案.



    在CMUR中所有的数据项都受到原著作权保护.

    TAIR相关文章

     


    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈