English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 29490/55136 (53%)
造訪人次 : 2001702      線上人數 : 369
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋
    主頁登入上傳說明關於CMUR管理 到手機版
    請使用永久網址來引用或連結此文件: http://ir.cmu.edu.tw/ir/handle/310903500/29116


    題名: Use of the bootstrap technique with small training sets for computer-aided diagnosis in breast ultrasound
    作者: Chen, DR;Kuo, WJ;Chang, RF;Moon, WK;Lee, CC
    貢獻者: 附設醫院外科部;China Med Coll & Hosp, Dept Gen Surg, Taichung, Taiwan;China Med Coll & Hosp, Dept Med Res, Taichung, Taiwan;Natl Chung Cheng Univ, Dept Comp Sci & Informat Engn, Chiayi, Taiwan;Seoul Natl Univ Hosp, Dept Diagnost Radiol, Seoul, South Korea
    日期: 2002
    上傳時間: 2010-09-24 14:22:20 (UTC+8)
    出版者: ELSEVIER SCIENCE INC
    摘要: We evaluated a series of pathologically proven breast tumors using an image-retrieval technique for classifying benign and malignant lesions. A total of 263 breast tumors (129 malignant and 134 benign) were retrospectively evaluated. The physician located regions-of-interest (ROI) of ultrasonic images and texture parameters (contrast, covariance and dissimilarity) were used in the process of the content-based image-retrieval technique. The accuracy of using the retrieval technique for classifying malignancies was 92.55% (236 of 255), the sensitivity was 94.44% (119 of 126), the specificity was 90.70% (117 of 129), the positive predictive value was 90.84% (119 of 131), and negative predictive value was 94.35% (117 of 124) for the proposed computer-aided diagnostic system. This computer-aided diagnosis system can provide a useful tool and its high negative predictive value could potentially,help avert benign biopsies. It is-unnecessary to perform any training procedures. This computer-aided diagnosis system can provide a second opinion for a sonographic interpreter; the main advantage in this proposed system is that we do not need any training. Historical cases can be directly added into the database and training of the diagnosis system again is not needed. With the growth of the database, more and more information can be collected and used as reference cases while performing diagnoses. This increases the flexibility of our diagnostic system. (E-mail: [email protected]) (C) 2002 World Federation for Ultrasound in Medicine Biology.
    關聯: ULTRASOUND IN MEDICINE AND BIOLOGY 28(7):897-902
    顯示於類別:[台中附設醫院] 期刊論文

    文件中的檔案:

    沒有與此文件相關的檔案.



    在CMUR中所有的資料項目都受到原著作權保護.

    TAIR相關文章

     


    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回饋